Shaking all over: controlled frequency vibration for concrete

The use of controlled frequency vibration for concrete continues to grow, writes Paul Jaworski Controlled frequency vibration (CFV) technology has been around since the mid-1990s for concrete pavement applications. The technology has seen a gradual increase in acceptance, particularly in certain applications. For the 0- to 37mm (1.5”) slump pavement mix designs, many contractors were experiencing material separation due to speeds over 8,000vibrations/minute (VPM). With the wide variability of concrete
November 28, 2018 Read time: 4 mins
CFVs have become the standard for use in concrete pavement construction in the US
The use of controlled frequency vibration for concrete continues to grow, writes Paul Jaworski


Controlled frequency vibration (CFV) technology has been around since the mid-1990s for concrete pavement applications. The technology has seen a gradual increase in acceptance, particularly in certain applications.

For the 0- to 37mm (1.5”) slump pavement mix designs, many contractors were experiencing material separation due to speeds over 8,000vibrations/minute (VPM). With the wide variability of concrete materials, moisture levels, batching uniformity, chemical incompatibilities, and slump loss rates, vibrator speeds needed to be highly controlled and predictable.

As a result, CFVs have become standard in the US construction sector. Concrete surfaces used in pedestrian ways, roads, and runways are now generally restricted to using CFVs for placement purposes. There are various manufacturers of hydraulic paving vibrators and the firms have developed an array of products that are similar in dynamics.

These paving vibrators feature sensors that tell the machine operator what speeds are being generated. With accurate speed control systems, the contractors learned to set the vibrator speed to deliver the desired results. From this learning curve, individual agencies have set vibrator speed ranges as specification for pavement mixes. Over a period of years in the US, CFVs have now become the standard for use in concrete pavement construction.

There are some important principles to be employed, with the data that is collected from vibrator speed logs being examined against the core samples from the pavement. This ensures that the effect of the vibration energy on the concrete can be properly evaluated. Higher vibrator speeds can cause surface problems from material separation. Those issues include permeability, poor aggregate arrangement, inconsistent surfaces and a greater susceptibility to freeze/thaw damage, resulting in a need for early repairs.

Improved CFV products have emerged in recent times as the technology has evolved. For decades, the success of CFVs did not grow proportionately to the growth in low-viscosity pumpable concrete for commercial applications.

However, the gap between commercial mix design and vibration technology is starting to close with the introduction of several CFV products in the industry. Progress has been attributed to better testing methodology, vibrator speed specifications, and more widespread training. Increased use of CFV technology shows that controlled vibration helps to minimise blemishes in concrete.

In the past, some mixes, placement variability, and slump values have seemed to be sufficiently vibrated when using conventional tools that have no accurately measured dynamic behaviour pattern. Performance characteristics of these tools has also varied from manufacturer to manufacturer. However more accurate analysis carried out in recent times has shown that these tools actually speed up when encountering lower concrete viscosities and will slow when viscosities are higher. Many of these tools are still in use, having survived since the 11,000VPM commercial specification was introduced by the American Concrete Institute (ACI) in the 1970s.


There are shortcomings with such equipment. When mixes feature a low-viscosity with large amounts of available water, uncontrolled frequency vibrators force water to the form faces, resulting in blemishes. But when vibrator speeds are controlled for low-viscosity concrete, blemishes are controlled.

Understandably, the use of CFV technology is on the rise, given the improved results these units can deliver. Industry studies have highlighted the separation issues that result when available water present in commercial mixes ends up as surface blemishes on form faces. And when a concrete structure is intended to display any architectural value in addition to its structural properties (such as for a bridge), patching and self-consolidating concrete have been viable options.

However a more simple answer to these over-vibration issues has been to control and lower the speeds so that these become more compatible with low-viscosity pumpable mixes. For modern projects, compatible vibrator speeds are applied to test samples during the pre-construction phase.

As contractors tackle the material, pumping, and batching variability issues, they are beginning to resolve surface issues by increasing the use of CFV technology, the quality of work delivered is generally improving.

In other words, controlled frequency vibration is here to stay.

*Paul Jaworski, Minnich Manufacturing Research and Development

Related Content

  • Higher productivity, lower cost asphalt plants
    February 14, 2012
    Manufacturers are producing innovative asphalt equipment, and operators are benefiting from this as Patrick Smithreports. Asphalt plant manufacturers and operators are understandably placing great emphasis on higher productivity but with lower costs. At the same time they are aware of environmental issues and the ever-increasing use of recycled material in mixes.
  • Groundbreaking calculator of greenhouse gas emissions
    February 9, 2012
    Time for CHANGER IRF launches CHANGER, a groundbreaking calculator of greenhouse gas emissions from road construction. Our world is changing, our climate is changing.
  • Groundbreaking calculator of greenhouse gas emissions
    April 12, 2012
    IRF launches CHANGER, a groundbreaking calculator of greenhouse gas emissions from road construction. Our world is changing, our climate is changing. Industry too is changing to meet the new social, environmental and economic challenges of our times. Already, the road sector has taken a decisive lead in this respect by transforming its practices and adopting new, more eco-friendly techniques and technologies. CHANGER is the latest flagship project in this evolution: the sign of an indust
  • Atlanta airport’s new apron
    October 12, 2012
    The new Maynard H Jackson Jr International Terminal at Hartsfield- Jackson Atlanta International Airport is now open for business. The 111,484m2 terminal features 12 gates, eight security checkpoints, separate levels for arrivals and departures, as well as a 148,831m2 concrete apron for aircraft to park on arrival. Archer Western won the contract to slipform the concrete apron, replace the existing Taxiway D, as well as other utilities and embankment work. The firm brought in one of its GOMACO paving trains