Skip to main content

Berghaus ProTec-Tor 120 successfully tested to DIN EN 1317, T3

German manufacturer Berghaus reports that its emergency opening ProTec-Tor 120 has successfully been tested according to the test criteria and requirements of DIN EN 1317. Test took place with a truck (TB 41) travelling at 70km/h and a car (TB 21) travelling at 80km/h. The ProTec-Tor 120 is a special element in our crash barrier system ProTec 100 (T3 / W2), according to the acceptance criteria of containment level T3. Up to now, in Germany such special elements were usually corroborated in static s
July 1, 2019 Read time: 2 mins
Berghaus ProTec-Tor 120: quickly and easily separated to create an opening
German manufacturer Berghaus reports that its emergency opening ProTec-Tor 120 has successfully been tested according to the test criteria and requirements of DIN EN 1317.


Test took place with a truck (TB 41) travelling at 70km/h and a car (TB 21) travelling at 80km/h.

The ProTec-Tor 120 is a special element in our crash barrier system ProTec 100 (T3 / W2), according to the acceptance criteria of containment level T3.

Up to now, in Germany such special elements were usually corroborated in static situations and as a computed simulation. But simulations are not always suitable for providing indubitable corroboration, particularly in terms of the dynamic forces and their impacts on special elements.

Because emergency openings are meanwhile increasingly required as safety devices in restraint systems with contraflow traffic, Berghaus instructed an accredited test lab to test the Pro-Tec-Tor 120.

In the standard crash test, the longitudinal force transfers and the functionality of the special element and also of the connected crash barrier system were documented on the basis of the two impact tests that were carried out. The emergency opening functioned perfectly even after the crash tests with a truck and car at high speeds with slight shifting of the system.

The ProTec-Tor 120 – as well as the ProTec-Tor 50 - are easily separated elements for mobile crash barriers that can be opened quickly in an emergency without needing tools. According to the company, only a couple of simple actions are needed to release the force-fit connection of the crash barriers to create an opening.

Related Content

  • Motorcycle-Guardrail Crashes: How can the risk of severe injury and fatality be reduced?
    July 23, 2012
    The problem: motorcyclist fatalities can occur from a variety of accidents. But in the United States in 2005, motorcyclists comprised 42% of fatalities due to guardrail collisions, whereas only 3% of vehicles on the roads were motorcycles (Gabler, 2007). More motorcyclists were killed in guardrail collisions than passengers of any other vehicle type in 2005 (Gabler, 2007). Guardrails cannot simply be removed to protect motorcyclists. However, improvements need to be made in several areas in order to keep mo
  • Novel twin layer paving technology saves time
    February 28, 2012
    German paver specialist Vögele reports that market acceptance is growing for its novel twin layer paving technology
  • Electreon completes first US dynamic charging
    December 14, 2023
    Testing of Electreon’s inductive dynamic charging technology along a Detroit road will start next year using a Ford E-Transit van equipped with the Electreon receiver.
  • Major advances in asphalt paving technology
    February 9, 2012
    Using the latest paving technology has allowed contractors to carry out difficult projects Contractors in Germany and Italy have been able to carry out very difficult asphalt paving applications, using the latest machines from Vögele and Volvo Construction Equipment respectively. In both instances these projects benefited greatly from the use of the latest generation equipment and it is debatable as to whether such high quality results could have been achieved with older machines.