Skip to main content

Stirling Lloyd in the fast lane: Waterproofing Warsaw’s Rowecki Bridge

Warsaw’s General Stefan Rowecki Bridge, or the Grota Bridge, is the second largest in the Polish capital and, as part of the Trasa Toruska expressway, it is the busiest. The structure, which opened in 1981, handles 150,000 cars daily, so repairs were always going to be tricky if minimal disruption to traffic was to occur. The steel orthotropic deck consists of two structurally independent parts – each with four traffic lanes. This meant that pedestrians and cyclists were restricted to two very narrow track
January 19, 2016 Read time: 4 mins
Colour contract made quality inspections easier
Warsaw’s General Stefan Rowecki Bridge, or the Grota Bridge, is the second largest in the Polish capital and, as part of the Trasa Toruska expressway, it is the busiest

The structure, which opened in 1981, handles 150,000 cars daily, so repairs were always going to be tricky if minimal disruption to traffic was to occur.  The steel orthotropic deck consists of two structurally independent parts – each with four traffic lanes. This meant that pedestrians and cyclists were restricted to two very narrow tracks, each separated from the road by traffic barriers, which made the bridge inaccessible to many people.

As a result, repair work to the bridge included widening to incorporate an extra two lanes in each direction for through-traffic, three lanes for local traffic and separate cycle and pedestrian paths.

Extreme weather conditions dictated that a high level of protection was needed. It was also important to ensure minimum maintenance in the future. Also, part of the bridge had to remain open during the work, to minimise traffic disruption.

Contractor B7 did reconstruction work on the 645m long x 40m wide bridge, while ZBM Inwestor Zastpczy was the lead engineering firm. They found that, once exposed, the deck had many irregularities including protrusions from the steel mesh.

After trialling several waterproofing solutions from different suppliers on the uneven deck profile, the contractors selected 2314 Stirling Lloyd’s Eliminator system, said Ned Birley, export general manager at Stirling Lloyd Polychem.

Stirling Lloyd’s authorised contractor, DWD Service prepared the deck and applied the waterproofing coat in phases based around reconstruction work.

The first phase was applying the Eliminator system to the pedestrian areas in July 2014. The second phase – consisting of waterproofing the main and new deck – was completed between April and June this year.

For both phases, the deck was prepared by shot-blasting metallic grit, followed by an independent assessment of the work that included measurement of the surface profile, dust assessment and ionic contamination. This was essential to ensure a strong bond between the substrate and the waterproofing, vital to the long-term performance of any membrane.

Adhesion pull-off tests confirmed a bond of between 3MPa and 4 MPa, more than the specified 2 MPa.

The Eliminator system comprised an initial anti-corrosive primer, ZED S94, to protect the newly exposed steel deck and enhance the bond between the deck and membrane. Once this had dried, the Eliminator system was sprayed on in two coats of contrasting colour – aiding on-site quality control and helping to ensure complete waterproofing integrity.

A final Tack Coat No. 2 was then applied. The thin film ‘hot melt’ adhesive ensures a strong bond between the membrane and surface. This adhesion between the deck, Eliminator and surfacing enables all elements to act as a composite, particularly important on a busy orthotropic steel deck. In turn, this helps to extend the life of both the surfacing and the structure. DWD was able to apply 1000m2 of the full bridge deck waterproofing system per day and which dried in less than an hour.

“Service and application conditions for the waterproofing were also extreme,” said Marcin Szwed, technical manager at Stirling Lloyd Polychem.

“Due to the phased nature of the work, the waterproofing system was applied and exposed to hot and cold weather conditions, with the deck temperature reaching up to 70°C at its peak. Using a system that can be applied in a wide range of temperatures and climatic conditions means that waterproofing installation can be carried out throughout the year, an essential feature for a large, phased project.”

Stirling Lloyd recently announced that Eliminator has gained European Technical Assessment (ETA) certification from the European Organisation for Technical Approvals (EOTA) through the British Board of Agrément (BBA). The ETA is based on the testing requirements in the  European Technical Approval Guideline (ETAG) 033. Eliminator is the first UK manufactured system to achieve this level of accreditation.

For more information on companies in this article

Related Content

  • Steel sealed on Stonecutters Bridge
    February 6, 2012
    The stone mastic asphalt surface being laid on the bridge deck. The Stonecutters Bridge in Hong Kong, the second longest spanning cable stayed bridge in the world, is a dual three-lane crossing of the Rambler Channel. It utilises 33,500tonnes of structural steel in the bridge deck; 32,000m3 of concrete in the towers and 65 steel deck units relying on 224 cables. Effectively protecting the megastructure's deck from the weather extremes (monsoon rains and extreme heat in the summer) and the high levels of tra
  • Stirling Lloyd launches Bond Coat 3, part of the Eliminator series
    July 7, 2016
    Stirling Lloyd Polychem has introduced a cold, spray-applied bond coat that it says provides enhanced adhesion values and superior in-situ performance Bond Coat 3, part of the Eliminator bridge deck waterproofing system, “represents a significant development” in the provision of tack and bond coats that are used to adhere the asphalt surfacing to the waterproofing. It provides a fast-curing tack-free, durable protective finish that resists contamination and damage from traffic. It removes the risk of
  • Long-lasting surface repairs for Avonmouth Bridge
    July 9, 2012
    Two technologies combined to give a heavily used bridge a new surface that should last for years The Avonmouth Bridge carries the M5 motorway over the River Avon, and is a vital part of the road infrastructure in south-west England, linking the counties of Somerset, Devon and Cornwall to the rest of the country. Completed in 1973, it carries commuters to the city of Bristol, and to South Wales, along with holidaymakers. The 1.4km long steel box girder bridge comprising a 16,000m2 steel decked central span a
  • Act FAST when it comes to bridge maintenance, argues Cliff Weston
    February 27, 2017
    Deck waterproofing remains critical to a bridge’s structural integrity for its design life, explains Cliff Weston, director of Stirling Lloyd To properly maintain deck waterproofing there must be a willingness to look at solutions based on whole-life costing rather than just short-term initial costs. There are lessons to be learned from examples of prematurely failed infrastructure due to a focus on initial short-term costs.