Skip to main content

CONTROLS widens capabilities for asphalt testing

The CONTROLS Group is widening its array of asphalt testing technologies. New from the Group is the PAVELAB50. This has been developed by the PAVELAB SYSTEMS division and is an automatic closed loop system for the separation and extraction of bitumen, filler and aggregates asphalt samples. This uses solvents, according to ASTM D2172 and EN 12697-1. The test methods are used for measuring bitumen in hot-mixed paving mixtures and paving samples for specification acceptance, service evaluation, control and res
March 3, 2016 Read time: 2 mins
CONTROLS is now offering more sophisticated asphalt testing systems
The 2139 CONTROLS Group is widening its array of asphalt testing technologies. New from the Group is the PAVELAB50. This has been developed by the PAVELAB SYSTEMS division and is an automatic closed loop system for the separation and extraction of bitumen, filler and aggregates asphalt samples. This uses solvents, according to ASTM D2172 and EN 12697-1. The test methods are used for measuring bitumen in hot-mixed paving mixtures and paving samples for specification acceptance, service evaluation, control and research. The machine is offered in two versions, with one including an innovative balancing system. The sample can be weighted at the end of each stage and related data is recorded and used for automatic result calculation.

The latest development in bitumen testing systems match the new fully automatic penetrometer PIVOT conforming to all the main international standards. The penetration needle is lowered with high precision by a stepper motor and the starting point is detected automatically. The device is zeroed and the penetration test is automatically performed with fully user-defined parameters without any operator intervention. The penetration value is measured by a high-resolution contactless displacement transducer and recorded in a portable USB memory stick. The operator interface is a colour touchscreen with multiple functions, including the real time display of penetration/time curve.

Another new system on display is the new Rolling Thin Film Oven RTFOT, it determines the resistance to hardening under the influence of heat and air. The oven has a touch-screen color display control panel, including timer function, visual warnings and digital air flow indicator. Standard’s temperature requirements (time to reach target temperature after switch on, target temperature adjustment after samples insertion) are fulfilled and exceeded.

For more information on companies in this article

Related Content

  • In control - with machine control technology
    June 21, 2016
    Advances with machine control technologies are providing major benefits right across the construction sector - Mike Woof writes With the massive bauma 2016 exhibition now having run its course, the construction sector look set to benefit from a range of new machine control technologies. These systems are being offered across a range of different segments in the equipment sector. Bulldozing was one of the first portions of the earthmoving segment to benefit from machine control systems, but a vast array o
  • Cat’s efficient M Series Wheeled Loaders
    May 14, 2014
    The new Cat 966M, 966M XE, 972M (pictured), and 972M XE Wheeled Loaders meet EU Stage IV emissions standards, and are said to offer considerable additional value including greater productivity, lower fuel consumption, improved operator efficiency and Cat Connect features. The four models have C9.3 ACERT engines equipped with a combination of proven electronic, fuel, air and after treatment components. Deep system integration is said to result in reduced emissions, improved performance and improved fuel
  • Adhesiveness control in asphalt mixes – from the project to production
    September 19, 2019
    Asphalt plant producer Ciber discusses asphalt mix properties The basic quality criterion of an asphalt mix is its adhesiveness; the adhesion capacity among materials. This adhesive capacity of the asphalt mix can be measured in the laboratory through qualitative or quantitative tests. The result of this analysis should be used as a reference for the improvement of the mix. In the laboratory this can be achieved using additives while at the plant it can be achieved using differing mixer technology an
  • Adhesiveness control in asphalt mixes – from the project to production
    September 19, 2019
    Asphalt plant producer Ciber discusses asphalt mix properties The basic quality criterion of an asphalt mix is its adhesiveness; the adhesion capacity among materials. This adhesive capacity of the asphalt mix can be measured in the laboratory through qualitative or quantitative tests. The result of this analysis should be used as a reference for the improvement of the mix. In the laboratory this can be achieved using additives while at the plant it can be achieved using differing mixer technology an