Worldwide action call on TRB barrier resolution

Highway authorities worldwide are being asked to take action on a Transportation Research Board (TRB) committee resolution.
February 16, 2012 Read time: 2 mins

Highway authorities worldwide are being asked to take action on a 2774 Transportation Research Board (TRB) committee resolution.

Earlier this year, the TRB AFB20 (2) Roadside Design Subcommittee on International Research approved the END Turned-Down ENDs resolution, which encourages road authorities to stop the use of fishtail, spoons or turned-down guardrail terminals and to use only crashworthy end treatments for their steel guardrail and concrete longitudinal barriers.

The traffic barrier ends resolution noted: "Turned-down terminals were developed and introduced in the 1960s to eliminate spearing of the rail into the passenger compartment of the impacting vehicle that often occurred with the fishtail or spoon full height, stand-up ends. While turned-down terminals were an improvement over the fishtail or spoon terminals, both field experience and full-scale crash testing have shown that vehicle roll over or launching is likely with turned-down terminals under high-speed impact conditions."

Based on observed crash test performance and reported field experience, the AFB20 (2) Subcommittee recommends that road authorities in all countries immediately prohibit new installations of fishtail or spoon terminals as well as turned-down terminals on the approach end of concrete barriers or steel beam guardrails on roads with operating speeds in excess of 80km/hour unless these ends are outside the defined clear zone and in other locations where end-on high-speed impacts are unlikely to occur or otherwise shielded from potential impacts.

"It is understood that system-wide replacement of existing turned-down ends or fishtail or spoon terminals, while beneficial, may not be practical or economically feasible. For new terminal installations at these locations road authorities should only specify the use of crashworthy terminals that have met appropriate testing criteria such as NCHRP 350 [National Cooperative Highway Research Program], MASH [Manual for Assessing Safety Hardware] or [European] EN 1317 (or their updates)," says the resolution.

"During any road construction restoration, rehabilitation and resurfacing projects, existing terminals should be updated with terminals that meet NCHRP 350, MASH or EN 1317 (or their updates) criteria.

"Turned-down terminals and fishtail terminals remain appropriate for trailing (downstream) ends of traffic barriers on divided highways and in other locations where end-on high-speed impacts are unlikely to occur.

"The Transportation Research Board AFB20(2) Roadside Design Subcommittee on International Research recognises the importance of the use of tested, state-of-the-art safety hardware and advocates the immediate implementation of of this resolution to make roads safer around the world."

For more information on companies in this article

Related Content

  • Workzone safety protects workforce and drivers
    February 15, 2012
    Highway construction work zones are dangerous places, and anything that can improve safety is welcomed as Patrick Smith reports. The safe and efficient flow of traffic through work zones is a major concern to transportation officials, industry, the public, businesses, and commercial motor carriers. This is the view of the US Federal Highway Administration (FHWA), which has developed the Highway Work Zone Safety Program to reduce the fatalities and injurious crashes in work zones, and to enhance traffic oper
  • Gregory Industries rolls out Safety Roller Barrier in North America
    June 19, 2017
    Gregory Industries, based in the US state of Ohio, is now the exclusive North American distributor for the Safety Roller Barrier system. Gregory has opted to market the innovative South Korean roller barrier technology in North America, offering a novel solution for road safety. The SRB is a MASH TL-4 longitudinal barrier that works by absorbing and converting shock energy into rotational energy. Prime locations for installations are areas where vehicles are exposed to frequent accidents. SRB is highly visi
  • A further crash test has been performed on SMA’s End Terminal
    July 5, 2016
    The latest crash test for the end terminal T4, made by SMA – Safety Modular Absorber - has been carried out to the EN 1317-7 standard. It was done in addition to the complete set of crash tests performed according to part 7 of the EN 1317. The test TT 6.3.110 had already been executed on the critical impact point selected by the CSI TestLab. SMA Road Safety said it shows “the excellence of the SMA end terminal to absorb the impacts coming from the opposite traffic direction”. The critical impact point is at
  • Swedish motorcycle test
    November 10, 2015
    In Sweden crash testing has been carried out using motorcycles for the first time. Four crash tests were carried out at the VTI crash laboratory in Linköping, Sweden, for the client, the insurance company Folksam. As a result, Swedish motorcyclists can expect safer barriers according to VTI, the Swedish National Road and Transport Research Insitute. The VTI have participated in two different projects with focus on better safety for motorcyclists. The first project was run in cooperation with the Swedish Mo