Skip to main content

Sandvik is now using Volvo Penta engines in its underground trucks and loaders

Sandvik Mining is now using Volvo Penta engines in its underground trucks and loaders. The advanced engines meet Tier 4 Interim/Stage IIIB emission standards and are claimed to reduce fuel and ventilation costs in comparison with other units. The Volvo Penta engineers designed a selective catalytic reduction (SCR) unit in the exhaust system that converts NOx gas into nitrogen and water. The Volvo Penta exhaust-treatment solution also reduces DPM levels without the need for a diesel particulate filter (DPF).
January 30, 2013 Read time: 2 mins
Volvo Penta’s clean burning engines suit duties for Sandvik’s underground machines
325 Sandvik Mining is now using 783 Volvo Penta engines in its underground trucks and loaders. The advanced engines meet Tier 4 Interim/Stage IIIB emission standards and are claimed to reduce fuel and ventilation costs in comparison with other units. The Volvo Penta engineers designed a selective catalytic reduction (SCR) unit in the exhaust system that converts NOx gas into nitrogen and water. The Volvo Penta exhaust-treatment solution also reduces DPM levels without the need for a diesel particulate filter (DPF). Sandvik says it opted for the Volvo Penta Tier 4 Interim engines because these offer a cleaner burning profile than other diesels that the firm evaluated.  Ventilation is a major cost for mine operations, so reducing the NOx and DPM levels can substantially reduce ventilation costs and improve underground working conditions. In addition to substantial costs for ventilation, there is considerable complexity to ensuring adequate fresh air is supplied to the right areas at the right times. Volvo Penta’s Tier 4 Interim engines require much less ventilation than other engines and can also provide huge cost savings.

Comparing Sandvik LH514 against a major competitor, the LH514 ventilation costs would be as much as 50% less, and fuel costs would be as much as 10% less. In addition to the reduced NOx and DPM levels, the Volvo Penta engines provide lower fuel consumption without sacrificing performance. As a result, their running cost/hour is among the lowest in the industry. The high-efficiency engines also generate less heat than higher-powered engines while doing the same amount of work. This is another critical factor for underground working, where heat generation from machines results in additional cooling to workings to ensure these remain within requirements. As the Volvo Penta Tier 4 Interim engines do not use cooled EGR, the heat rejection and radiator size is significantly reduced. This allows Sandvik to use the same radiator size as a Tier 2 engine, whereas, DPF technology requires larger radiators and improves visibility for the operator, without raising the overall height of the vehicle.

%$Linker: 2 External <?xml version="1.0" encoding="utf-16"?><dictionary /> 0 0 0 oLinkExternal www.VolvoPenta.com www.VolvoPenta.com false http://www.volvopenta.com/ false false%>
%$Linker: 2 External <?xml version="1.0" encoding="utf-16"?><dictionary /> 0 0 0 oLinkExternal Construction.Sandvik.com<br /> Construction.Sandvik.com false http://construction.sandvik.com/ false false%>

 

%$Linker: 2 Internal <?xml version="1.0" encoding="utf-16"?><dictionary /> 2 11560 0 oLinkInternal <span class="oLinkInternal"><span class="oLinkInternal">View more videos</span></span> Video false /event-news/bauma-2013/video/ true false%>

For more information on companies in this article

Related Content

  • DX300 and DX340 get stage IIIB engines at INTERMAT
    January 6, 2017
    Doosan’s DX300LC-3 and DX340LC-3 excavators get the Korean maker’s DL08K common rail six-cylinder turbocharged diesel engine meeting stage IIIB emission regulations thanks to EGR and DPF technologies.
  • DX300 and DX340 get stage IIIB engines at INTERMAT
    March 7, 2012
    Doosan’s DX300LC-3 and DX340LC-3 excavators get the Korean maker’s DL08K common rail six-cylinder turbocharged diesel engine meeting stage IIIB emission regulations thanks to EGR and DPF technologies.
  • ATS has great screen presence
    March 27, 2013
    ATS’ polyurethane wire mesh screens for industrial screenings are said to offer a wide range of advantages including long service life; easy handling; less pegging and blinding; and high screening performance with perfect undersize calibration during the screen’s working lifetime. In addition, the firm says its wire mesh screens have less sound emanating from them, while reducing the weight of the vibrating screen is said to have improved its operation. The ATS screens are equipped with hooks and fitted in
  • Haver & Boecker is adding to its screen range with wire and polyurethane screen decks
    February 8, 2013
    Haver & Boecker is expanding its screen range with the addition of the Ty-Wire hybrid screen deck and of ultrasound screen decks. Ty-Wire hybrid screens use wire that is covered in polyurethane, providing a greater open area than a standard PU screen but with a lifetime that can be 4-6 times longer.