Skip to main content

JCB engine uses ‘mini-SCR’ to meet Tier 4 Final

JCB says its Ecomax Stage 4/Tier 4 Final engine can be engineered into many existing machines without needing additional space by using a ‘one can’ selective catalytic reduction (SCR). According to the company’s chief technology officer, Tim Burnhope, in many cases the mini SCR on the Stage 4/Tier 4 Final Ecomax engine can be positioned in the same space occupied by the exhaust silencer on previous generations. He said, “Our engine is already so clean that we only need 2% to 3% of urea, which allows us to u
January 6, 2017 Read time: 2 mins
The small SCR will replace the silencer in many installations
255 JCB says its Ecomax Stage 4/Tier 4 Final engine can be engineered into many existing machines without needing additional space by using a ‘one can’ selective catalytic reduction (SCR).

According to the company’s chief technology officer, Tim Burnhope, in many cases the mini SCR on the Stage 4/Tier 4 Final Ecomax engine can be positioned in the same space occupied by the exhaust silencer on previous generations.

He said, “Our engine is already so clean that we only need 2% to 3% of urea, which allows us to use a very compact SCR system. Many of our competitors have two or three canisters – one for the SCR, one for a DOC and another for a DPF – and that requires a lot more space.” Our SCR is so compact that, in many cases, there is no need for any bodywork alterations.”

The new engine is said to be 5% more fuel efficient than the Stage IIIB/Tier 4 Interim version, which is itself some 10% more economical than the Stage IIIA version. In its Stage IIIB/Tier 4 Interim guise the Ecomax engine has exhaust gas recirculation and variable turbocharger geometry but does not require a DPF. Power ratings now go up to 129kW, meaning JCB is now fitting the Ecomax in excavators up to the 22tonnes operating weight JS220.

According to Burnhope, the Ecomax is 10% more fuel efficient than the engine it replaces and would save a typical JS220 owner €5,200 in fuel over three years.

When asked during a press conference if a six-cylinder version of the Ecomax was likely in the near future, the company said, “We consider all options and the deciding factor is whether it will save the customer fuel.”

Stand: F7.713/1

%$Linker: 2 Asset <?xml version="1.0" encoding="utf-16"?><dictionary /> 2 12802 0 oLinkExternal www.JCB.com www.JCB.com false /EasySiteWeb/GatewayLink.aspx?alId=12802 false false%>

%$Linker: 2 Internal <?xml version="1.0" encoding="utf-16"?><dictionary /> 2 11560 0 oLinkInternal <span class="oLinkInternal"><span class="oLinkInternal">View more videos</span></span> Video false /event-news/bauma-2013/video/ true false%>

For more information on companies in this article

Related Content

  • Perkins completes line-up of four-cylinder engines for Tier IV Final/Stage 4
    April 16, 2013
    Perkins has completed its line-up of four-cylinder engines for Tier 4 Final/Stage IV with the introduction of the 854F-E34TA – the latest in its 800 Series range. The compact, four-cylinder, 3.4litre engine incorporates specially developed SCR technology for the first time. Packaged separately from the DOC module, it can be mounted in either a horizontal or vertical position, giving OEMs of compact machinery greater installation flexibility in the engine bay.
  • Sandvik is now using Volvo Penta engines in its underground trucks and loaders
    January 6, 2017
    Sandvik Mining is now using Volvo Penta engines in its underground trucks and loaders. The advanced engines meet Tier 4 Interim/Stage IIIB emission standards and are claimed to reduce fuel and ventilation costs in comparison with other units. The Volvo Penta engineers designed a selective catalytic reduction (SCR) unit in the exhaust system that converts NOx gas into nitrogen and water. The Volvo Penta exhaust-treatment solution also reduces DPM levels without the need for a diesel particulate filter (DPF).
  • Sandvik is now using Volvo Penta engines in its underground trucks and loaders
    January 30, 2013
    Sandvik Mining is now using Volvo Penta engines in its underground trucks and loaders. The advanced engines meet Tier 4 Interim/Stage IIIB emission standards and are claimed to reduce fuel and ventilation costs in comparison with other units. The Volvo Penta engineers designed a selective catalytic reduction (SCR) unit in the exhaust system that converts NOx gas into nitrogen and water. The Volvo Penta exhaust-treatment solution also reduces DPM levels without the need for a diesel particulate filter (DPF).
  • John Deere Power Systems completes engine line-up
    January 6, 2017
    John Deere Power Systems used bauma to complete its engine line-up for Tier 4 Final/Stage IV emissions regulations. This included the arrival of the PowerTechTM PWL 4.5L engine, which meets emissions regulations without a diesel particulate filter (DPF). Spanning outputs from 63-104kW, this four-cylinder, 4.5litre engine offers reduced cost and improves engine packaging by eliminating the DPF, said Deere. However, the engine uses selective catalytic reduction (SCR), a diesel oxidation catalyst (DOC) and coo