Skip to main content

Caterpillar’s KO loader

The new redesigned Cat K Series Small Wheel Loaders—924K, 930K and 938K— being unveiled at Intermat 2012 are said to incorporate new Stage IIIB/Tier 4 Interim emissions standard engines and many new performance enhancing features. An efficient electronically controlled hydrostatic drive system, new optimised Z-bar loader linkage, refined operator's station and a choice of couplers and buckets for best matching the machine to the application are among the notable features on the debuting wheel loader models,
January 6, 2017 Read time: 3 mins
Caterpillars 938k Wheel Loader live at INTERMAT
The new redesigned 2294 CAT K Series Small Wheel Loaders—924K, 930K and 938K— being unveiled at Intermat 2012 are said to incorporate new Stage IIIB/Tier 4 Interim emissions standard engines and many new performance enhancing features.

An efficient electronically controlled hydrostatic drive system, new optimised Z-bar loader linkage, refined operator's station and a choice of couplers and buckets for best matching the machine to the application are among the notable features on the debuting wheel loader models.

Predecessor small wheel loaders—924H, 924Hz, 928Hz, 930H, 938H — will be available in markets having lesser fuel quality and less-stringent emissions standards.

The Cat C6.6 ACERT engine powers the three new K-Series wheel loaders and is said to work efficiently with the machines to deliver fuel savings up to 30%, compared with H-Series models. Emissions-control technology includes a diesel particulate filter that utilises passive regeneration.

K-Series models are equipped with a step-less, four-range, hydrostatic drive system that is said by Caterpillar to allow independent control of ground speed and engine speed for efficient operation of hydraulically powered work tools. A new creeper control feature further improves low speed operations by allowing the operator to reduce maximum ground speed to 1km/h. An operator-controlled rimpull-control system is said to help reduce wheel spin and, consequently, tyre wear, and a standard front differential lock enhances traction. 

Caterpillar says optimised Z-bar loader linkage on its K Series wheel loaders blends the breakout power of Z-bar linkage with the parallel-lift and load-handling characteristics of Cat VersaLink or IT (Integrated Toolcarrier) linkage. The new linkage, available in both standard- and high-lift configurations, is said to accept pin-on tools and a Cat Fusion coupler that is compatible with competitive work tools. The new linkage is designed to work with Cat Performance Series buckets, said to be designed for efficient loading, high fill factors, improved material retention and lowered fuel consumption.

New operator's station features include an automatic temperature control, curved front windshield, heated rear window with intermittent wiper, and a Soft Touch control panel. The electronic joystick for implement control is seat-mounted, adjustable and incorporates integral controls for auxiliary hydraulics, directional shifting and differential lock. In-cab sound levels are said by Caterpillar to be reduced to a typical level of 66 dB (A), (68 dB certified), down from 74 dB (A) in the H-Series models
.
Kick-out functions for boom lift, boom lower and tilt are standard and said to be easily programmable by pushing and holding a button on the Soft Touch panel.

%$Linker: External 0 0 0 oLinkExternal <span class="mouselink">www.cat.com</span> Cat false http://www.cat.com/ false false%>

Hall: 5B Stand: J023

%$Linker: 2 Internal 2 4824 0 oLinkInternal <span class="oLinkInternal"><span class="oLinkInternal">View more videos</span></span> Video false /event-news/intermat-2012/video/ true false%>

For more information on companies in this article

Related Content

  • Peri launched UP MDS Formwork at INTERMAT 2012
    February 3, 2012
    Peri is unveiling its new UP MDS shoring tower to all markets outside France at INTERMAT 2012. The shoring tower is equipped with working platforms hanging from the handrails, providing a high level of security during the erection and dismantling phases, and a significantly reduced exposure to musculoskeletal disorders (MSDs). The working platform sets an automatic working position 1m below the handrail and follows the top of the tower. The system improves productivity by optimising weight (total weight of
  • INTERMAT launch for Ammann UniBatch asphalt mixing plants
    January 6, 2017
    Ammann is using INTERMAT to reveal its UniBatch range of asphalt mixing plants. With capacities from 80-350 tonnes/hour, this new plant type incorporates flexibility, and a larger selection of modules to allow the system to be expanded as required. Energy efficiency and reduced emissions are key elements of the UniBatch range, which is said to be is compatible with all of Ammann's recycling technologies. Mixer capacities extend from 1.3-4.3tonnes, hot silo storage is from 45-120tonnes and mixed material sto
  • INTERMAT launch for Ammann UniBatch asphalt mixing plants
    April 12, 2012
    Ammann is using INTERMAT to reveal its UniBatch range of asphalt mixing plants. With capacities from 80-350 tonnes/hour, this new plant type incorporates flexibility, and a larger selection of modules to allow the system to be expanded as required. Energy efficiency and reduced emissions are key elements of the UniBatch range, which is said to be is compatible with all of Ammann's recycling technologies. Mixer capacities extend from 1.3-4.3tonnes, hot silo storage is from 45-120tonnes and mixed material sto
  • John Deere to show entire Final Tier 4/Stage IV diesel engine line-up
    January 6, 2017
    John Deere Power Systems’ (JDPS) entire Final Tier 4/Stage IV diesel engine line-up can be seen with the company showing its familiar PowerTech displacements of 2.9, 4.5, 6.8, 9 and 13.5litres. United States Final Tier 4 and European Union Stage IV emissions regulations for mobile off-highway diesel engines 56kW and above will be implemented in stages starting in 2014 and 2015. These standards maintain the particulate matter (PM) levels established by Interim Tier 4/Stage III B regulations while requiring a