Skip to main content

Cortec provides MCI 2020 protection for Croatia’s Krk Bridge

Krk Bridge is a 1.4km reinforced concrete arch bridge connecting the Croatian island of Krk to the mainland and carrying over a million vehicles per year. The longer of the bridge's two arches is the longest concrete arch in the world outside of China.
February 5, 2020 Read time: 2 mins
Cortec’s MCI 2020 surface protection system is being used in the Krk Bridge preservation project

Strong winds often cause the 1.4km structure to be closed. Also, the salt air has corroded the bridge that was opened in 1980; it requires constant maintenance to provide the next 36 years of its expected service. It costs around €1 million every year in regular and extra maintenance.

Cortec says that application of its MCI 2020 will stop further corrosion of reinforcing metals and will be used in a 30-year maintenance plan where field investigation of the current status and the preservation project design was done by IGH, Institute for Civil Engineering, based in the Croatian capital Zagreb. According to the results, the concrete is contaminated to the depth of the main reinforcement, so the existing concrete is removed to this depth.

After the removal of contaminated concrete layer the cleaned concrete surface is treated with MCI 2020 (Migrating Corrosion Inhibitor) - a surface-applied corrosion inhibitor designed to migrate through concrete structures and seek out the steel reinforcement bars in concrete. A feature of MCI 2020 is that if it is not in direct contact with metals, it will migrate a considerable distance through concrete to provide protection.

Detailed visual inspection of the concrete and reinforcement is carried out and any faults are eliminated by removal of the concrete and cleaning the rebar.  If corrosion is found then MCI 2020 is applied.

Before applying the mortar, the surface must be thoroughly moistened; any excess water must be removed. Repair mortar is then applied by spray onto the surface treated with the MC 2020 inhibitor in a single layer. This provides excellent adhesion, so no binding layer is required, according to Cortec.

Related Content

  • Wirtgen paving technology takes off at Frankfurt
    February 27, 2017
    Time was at a premium for Wirtgen machinery when resurfacing the runway at Frankfurt/Main Airport Europe’s third largest airport, Frankfurt/Main, has new surface course on runways about every seven year, including the centre runway, the most-frequently used section.
  • Energy efficient cement testing solution
    February 27, 2012
    In determining the mechanical strength of cement, the European Standard EN 196 prescribes both compressive and flexural tests, so when Italian company Tecnotest designed its current generation of cement testing machines, the aim was to obtain highly accurate results over the full scale despite the wide range involved by implementing a dual scale in a single test bay, using load cells as dynamometers.
  • Improving road safety in Europe?
    July 24, 2012
    New plans by the European Commission are being proposed in a bid to reduce accident levels on the road. The changes are being made in a bid to reduce accident levels caused by defective vehicles. Under the new rules, all motorcycles and scooters would require technical inspections at regular intervals.
  • The ABG Advantage: What separates these pavers from the competition?
    September 25, 2024
    There are a great many roadbuilding products out there. Sometimes it can be hard to separate the best from the rest.